Attributes

BrandAFCON
Figure NumberAF776
MaterialSteel
FinishPlain, Electro Galvanized
Filter Attributes
{"Brand":"AFCON","Figure Number":"AF776","Material":"Steel","Finish":"Plain, Electro Galvanized","Pipe Type":"Steel","Solutions":"Mechanical & Plumbing Systems, Commercial & Residential, Data Centers, Industrial, Energy & Power, Mining, Fire Protection, Oil & Gas, Water & Wastewater","Size Range":"Service Pipe: 2 1/2\" through 8\" Carbon Steel, Brace Pipe: 1\" or 1 1/4\" Sch. 40","Service":"Designed to rigidly brace piping systems subjected to lateral seismic loads. May also be installed to brace piping systems subjected to vertical seismic loads. For vertical load capacities, reference OSHPD OPM-0351-13.","Approvals":"FM Approved (FM 1950-10 & FM 1950-13). OSHPD Pre-Approved (OPM-0351-13 and OPA-2804-10). Complies with the hanging and bracing requirements listed in NFPA 13.","Features":"Visual indication of proper assembly when the head of the set screw bottoms out on the hoop ends.","Installation Instructions":"Place the OSHPD Lateral Brace Clamp over the service pipe to be braced and slide the Sch. 40 brace pipe through the hoop ends. The end of the brace pipe must extend at least 1\" past the hoop ends.; Note: The brace pipe may be installed above or below the service pipe.; Ensure brace pipe is set to the desired installation brace angle.; Torque the set screws alternately and equally until the head of the set screw bottoms out on the hoop ends.; For riser/4-way brace installations, two OSHPD Lateral Brace Clamps must be installed within 6\" of each other.; Fire Protection applications shall also be installed per the requirements of NFPA 13 and local codes.","Ordering":"Specify service pipe size, brace pipe size, figure number, finish and description.","Category":"Support Systems > Seismic Bracing > Seismic Braces","Equivalent Products":"Anvil 776; AFCON 035; Caddy CSBQG, CSBQICKL; PHD 015; Tolco 1001"}
Equivalent Products
{"manufacturer":"Anvil","productNumber":"776"}, {"manufacturer":"AFCON","productNumber":"035"}, {"manufacturer":"Caddy","productNumber":"CSBQG, CSBQICKL"}, {"manufacturer":"PHD","productNumber":"015"}, {"manufacturer":"Tolco","productNumber":"1001"}
Upc Codes
690291235290, 690291235535, 690291235610, 690291242458, 690291242465, 690291242472, 690291242489, 690291242496, 690291242502, 690291242519, 690291242526, 690291242595, 690291243424, 690291243455, 690291243462, 690291243479, 690291243486, 690291243493, 690291243509, 690291243516, 690291243523, 690291243530, 690291243547, 690291243554, 69029123529, 69029123553, 69029123561, 69029124245, 69029124246, 69029124247, 69029124248, 69029124249, 69029124250, 69029124251, 69029124252, 69029124259, 69029124342, 69029124345, 69029124346, 69029124347, 69029124348, 69029124349, 69029124350, 69029124351, 69029124352, 69029124353, 69029124354, 69029124355
Algolia Submittal/resource/AF776 OSHPD Lateral Brace Clamp Submittal
Gtin690291235290

Description

Size Range: Service Pipe: 2 1/2" through 8" Carbon Steel, Brace Pipe: 1" or 1 1/4" Sch. 40 Material: Carbon Steel Finish: Plain or Electro-Galvanized per ASTM B633 Service: Designed to rigidly brace piping systems subjected to lateral seismic loads. May also be installed to brace piping systems subjected to vertical seismic loads. For vertical load capacities, reference OSHPD OPM-0351-13. Approvals: FM Approved (FM 1950-10 & FM 1950-13). OSHPD Pre-Approved (OPM-0351-13 and OPA-2804-10). Complies with the hanging and bracing requirements listed in NFPA 13. Features: Visual indication of proper assembly when the head of the set screw bottoms out on the hoop ends. Installation Instructions: Place the OSHPD Lateral Brace Clamp over the service pipe to be braced and slide the Sch. 40 brace pipe through the hoop ends. The end of the brace pipe must extend at least 1" past the hoop ends. Note: The brace pipe may be installed above or below the service pipe. Ensure brace pipe is set to the desired installation brace angle. Torque the set screws alternately and equally until the head of the set screw bottoms out on the hoop ends. For riser/4-way brace installations, two OSHPD Lateral Brace Clamps must be installed within 6" of each other. Fire Protection applications shall also be installed per the requirements of NFPA 13 and local codes. Ordering: Specify service pipe size, brace pipe size, figure number, finish and description.

Variations (24)

0500603709

Code SystemASC Item Number

0500603725

Code SystemASC Item Number

0500603808

Code SystemASC Item Number

0500603824

Code SystemASC Item Number

0500603907

Code SystemASC Item Number

0500603923

Code SystemASC Item Number

0500604004

Code SystemASC Item Number

0500604020

Code SystemASC Item Number

0500604103

Code SystemASC Item Number

0500604129

Code SystemASC Item Number

0500604202

Code SystemASC Item Number

0500604228

Code SystemASC Item Number

0500610001

Code SystemASC Item Number

0500610027

Code SystemASC Item Number

0500610100

Code SystemASC Item Number

0500610126

Code SystemASC Item Number

0500610209

Code SystemASC Item Number

0500610225

Code SystemASC Item Number

0500610308

Code SystemASC Item Number

0500610324

Code SystemASC Item Number

0500610407

Code SystemASC Item Number

0500610423

Code SystemASC Item Number

0500610506

Code SystemASC Item Number

0500610522

Code SystemASC Item Number

Specifications

BrandAFCON
Figure NumberAF776
MaterialSteel
FinishPlain, Electro Galvanized
Pipe TypeSteel
SolutionsMechanical & Plumbing Systems, Commercial & Residential, Data Centers, Industrial, Energy & Power, Mining, Fire Protection, Oil & Gas, Water & Wastewater
Size RangeService Pipe: 2 1/2" through 8" Carbon Steel, Brace Pipe: 1" or 1 1/4" Sch. 40
ServiceDesigned to rigidly brace piping systems subjected to lateral seismic loads. May also be installed to brace piping systems subjected to vertical seismic loads. For vertical load capacities, reference OSHPD OPM-0351-13.
ApprovalsFM Approved (FM 1950-10 & FM 1950-13). OSHPD Pre-Approved (OPM-0351-13 and OPA-2804-10). Complies with the hanging and bracing requirements listed in NFPA 13.
FeaturesVisual indication of proper assembly when the head of the set screw bottoms out on the hoop ends.
Installation Instructions
Place the OSHPD Lateral Brace Clamp over the service pipe to be braced and slide the Sch. 40 brace pipe through the hoop ends. The end of the brace pipe must extend at least 1" past the hoop ends.; Note: The brace pipe may be installed above or below the service pipe.; Ensure brace pipe is set to the desired installation brace angle.; Torque the set screws alternately and equally until the head of the set screw bottoms out on the hoop ends.; For riser/4-way brace installations, two OSHPD Lateral Brace Clamps must be installed within 6" of each other.; Fire Protection applications shall also be installed per the requirements of NFPA 13 and local codes.
OrderingSpecify service pipe size, brace pipe size, figure number, finish and description.
CategorySupport Systems > Seismic Bracing > Seismic Braces
Equivalent ProductsAnvil 776; AFCON 035; Caddy CSBQG, CSBQICKL; PHD 015; Tolco 1001

PDF Documents