94 Wide Throat Top Beam Clamp

Scraped SKU: 3499 2026-06-05 01:11:08

Attributes

BrandAnvil
Figure Number94
MaterialDuctile Iron
FinishPlain, Zinc Plated
Filter Attributes
{"Brand":"Anvil","Figure Number":"94","Material":"Ductile Iron","Finish":"Plain, Zinc Plated","Solutions":"Mechanical & Plumbing Systems, Commercial & Residential, Data Centers, Industrial, Energy & Power, Mining, Fire Protection, Oil & Gas, Water & Wastewater","Size Range":"5/8\" and 3/4\"","Service":"Recommended for use under roof installations with bar joist type construction, or for attachment to the top flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joists or flange does not exceed 1-5/16\".","Approvals":"Complies with Federal Specification A-A-1192A (Type 19), WW-H-171-E (Type 19), ANSI/MSS SP-69 and MSS SP-58 (Type 19), UL Listed.","How to size":"Size of clamp is determined by size of rod to be used.","Installation":"Follow maximum recommended set screw torque values per MSS-SP-69.","Ordering":"Specify rod size, figure number, name of clamp and finish.","Category":"Support Systems > Pipe Hangers & Supports > Structural Attachments > Beam Clamps","Equivalent Products":"B-Line B3033; PHD 360; C&P 192 (5/8-3/4); Empire 61; B-Line B3033; PHD 360; C&P 192 ( 5/8- 3/4); Empire 61"}
Equivalent Products
{"manufacturer":"B-Line","productNumber":"B3033"}, {"manufacturer":"PHD","productNumber":"360"}, {"manufacturer":"C&P","productNumber":"192 (5/8-3/4)"}, {"manufacturer":"Empire","productNumber":"61"}, {"manufacturer":"B-Line","productNumber":"B3033"}, {"manufacturer":"PHD","productNumber":"360"}, {"manufacturer":"C&P","productNumber":"192 ( 5/8- 3/4)"}, {"manufacturer":"Empire","productNumber":"61"}
Upc Codes690291134418, 690291134425, 690291607035, 690291607042, 69029113442, 69029160703, 69029160704, 69029113441
Algolia Submittal/resource/94 Wide Throat Top Beam Clamp Submittal
Gtin690291134418

Description

The Anvil Wide Throat Top Beam Clamp has a ductile iron body with hardened steel cup point set screw and locknut. Clamps to bar joists or top flanges. UL Listed. Features: Provides clamping to bar joists which are directly under roof installations. Provides for vertical hanger rod installed offset from the edge of the beam flange. Ductile iron body assures full thread engagement of rod. Specifications: Size Range: 5/8" and 3/4" Material: Ductile iron body, hardened steel cup point set screw and locknut. Finish: Plain and Zinc Plated (Hot-Dip Galvanized optional) Service: Recommended for use under roof installations with bar joist type construction, or for attachment to the top flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joists or flange does not exceed 1-5/16". Approvals: Complies with Federal Specification A-A-1192A (Type 19), WW-H-171-E (Type 19), ANSI/MSS SP-69 and MSS SP-58 (Type 19), UL Listed. Additional Information: How to size: Size of clamp is determined by size of rod to be used. Installation: Follow maximum recommended set screw torque values per MSS-SP-69. Ordering: Specify rod size, figure number, name of clamp and finish.

Variations (4)

0500009238

Code SystemASC Item Number

0500009246

Code SystemASC Item Number

0500010210

Code SystemASC Item Number

0500010236

Code SystemASC Item Number

Specifications

BrandAnvil
Figure Number94
MaterialDuctile Iron
FinishPlain, Zinc Plated
SolutionsMechanical & Plumbing Systems, Commercial & Residential, Data Centers, Industrial, Energy & Power, Mining, Fire Protection, Oil & Gas, Water & Wastewater
Size Range5/8" and 3/4"
Service
Recommended for use under roof installations with bar joist type construction, or for attachment to the top flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joists or flange does not exceed 1-5/16".
ApprovalsComplies with Federal Specification A-A-1192A (Type 19), WW-H-171-E (Type 19), ANSI/MSS SP-69 and MSS SP-58 (Type 19), UL Listed.
How to sizeSize of clamp is determined by size of rod to be used.
InstallationFollow maximum recommended set screw torque values per MSS-SP-69.
OrderingSpecify rod size, figure number, name of clamp and finish.
CategorySupport Systems > Pipe Hangers & Supports > Structural Attachments > Beam Clamps
Equivalent ProductsB-Line B3033; PHD 360; C&P 192 (5/8-3/4); Empire 61; B-Line B3033; PHD 360; C&P 192 ( 5/8- 3/4); Empire 61

PDF Documents