Attributes

BrandAFCON
Figure NumberAF001
MaterialSteel
FinishPlain, Electro Galvanized
Filter Attributes
{"Brand":"AFCON","Figure Number":"AF001","Material":"Steel","Finish":"Plain, Electro Galvanized","Pipe Type":"Steel","Pipe Connection":"Seismic Brace","Solutions":"Mechanical & Plumbing Systems, Commercial & Residential, Data Centers, Industrial, Energy & Power, Mining, Fire Protection, Oil & Gas, Water & Wastewater","Size Range":"Service Pipe: 1\" through 4\", Brace Pipe: 1\" or 1 1/4\" Sch. 40","Service":"Designed to rigidly brace and restrain piping systems subjected to lateral seismic loads. May also be installed to brace piping systems subjected to vertical seismic loads. For vertical load capacities, reference OSHPD OPM-0351-13.","Approvals":"cULus Listed (UL 203a) and FM Approved (FM 1950-10 & FM 1950-13). OSHPD Pre-Approved (OPM-0351-13 and OPA-2804-10). Complies with the hanging and bracing requirements listed in NFPA 13.","Features":"Field adjustable design requires no threading of the brace pipe; Indicator clip provides a visual indication that the desired torque value has been achieved","Installation Instructions":"Place the 3/8\" diameter threaded rod hoop over the service pipe and slide the Sch. 40 brace pipe through the open ends of the threaded rod hoop. The end of the brace pipe must extend at least 2\" past the channel bracket.; Note: The brace pipe may be installed above or below the service pipe.; Ensure brace pipe is set to the desired installation brace angle.; Torque hex nuts alternately and equally to the listed torque. Ensure the indicator clip is completely flattened and the brace pipe is tight against the service pipe.; For riser/4-way brace installations, two Q Brace clamps must be installed within 6\" of each other.; Fire Protection applications shall also be installed per the requirements of NFPA 13 and local codes.","Ordering":"Specify service pipe size, brace pipe size, figure number, finish and description.","Category":"Support Systems > Seismic Bracing > Seismic Braces","Equivalent Products":"Anvil 770; AFCON 001, 020; PHD 010; Tolco 1000"}
Equivalent Products{"manufacturer":"Anvil","productNumber":"770"}, {"manufacturer":"AFCON","productNumber":"001, 020"}, {"manufacturer":"PHD","productNumber":"010"}, {"manufacturer":"Tolco","productNumber":"1000"}
Upc Codes
690291232749, 690291232763, 690291232787, 690291232794, 690291232947, 690291232954, 690291232961, 690291232978, 690291232992, 690291233005, 690291233012, 690291233029, 690291233036, 690291233043, 690291242632, 690291242656, 690291242663, 690291242670, 690291242694, 690291242700, 690291242717, 690291242724, 690291242731, 690291242748, 690291242755, 690291242762, 690291242779, 690291242892, 65280800101, 65280800113, 65280800115, 65280800102, 65280800125, 65280800103, 65280800104, 65280800118, 65280800119, 65280800026, 65280800027, 65280800028, 65280800029, 65280800130, 65280800134, 65280800107, 65280800140
Algolia Submittal/resource/AF001 Q Brace Clamp Submittal
Gtin690291232749

Description

Size Range: Service Pipe: 1" through 4", Brace Pipe: 1" or 1 1/4" Sch. 40 Material: Carbon steel Finish: Plain or Electro-Galvanized per ASTM B633 Service: Designed to rigidly brace and restrain piping systems subjected to lateral seismic loads. May also be installed to brace piping systems subjected to vertical seismic loads. For vertical load capacities, reference OSHPD OPM-0351-13. Approvals: cULus Listed (UL 203a) and FM Approved (FM 1950-10 & FM 1950-13). OSHPD Pre-Approved (OPM-0351-13 and OPA-2804-10). Complies with the hanging and bracing requirements listed in NFPA 13. Features: Field adjustable design requires no threading of the brace pipe Indicator clip provides a visual indication that the desired torque value has been achieved Installation Instructions: Place the 3/8" diameter threaded rod hoop over the service pipe and slide the Sch. 40 brace pipe through the open ends of the threaded rod hoop. The end of the brace pipe must extend at least 2" past the channel bracket. Note: The brace pipe may be installed above or below the service pipe. Ensure brace pipe is set to the desired installation brace angle. Torque hex nuts alternately and equally to the listed torque. Ensure the indicator clip is completely flattened and the brace pipe is tight against the service pipe. For riser/4-way brace installations, two Q Brace clamps must be installed within 6" of each other. Fire Protection applications shall also be installed per the requirements of NFPA 13 and local codes. Ordering: Specify service pipe size, brace pipe size, figure number, finish and description.

Variations (45)

0500600002

Code SystemASC Item Number

0500600028

Code SystemASC Item Number

0500600069

Code SystemASC Item Number

0500600085

Code SystemASC Item Number

0500600200

Code SystemASC Item Number

0500600226

Code SystemASC Item Number

0500600309

Code SystemASC Item Number

0500600325

Code SystemASC Item Number

0500600408

Code SystemASC Item Number

0500600424

Code SystemASC Item Number

0500600507

Code SystemASC Item Number

0500600523

Code SystemASC Item Number

0500600606

Code SystemASC Item Number

0500600622

Code SystemASC Item Number

0500606009

Code SystemASC Item Number

0500606025

Code SystemASC Item Number

0500606108

Code SystemASC Item Number

0500606124

Code SystemASC Item Number

0500606207

Code SystemASC Item Number

0500606223

Code SystemASC Item Number

0500606306

Code SystemASC Item Number

0500606322

Code SystemASC Item Number

0500606405

Code SystemASC Item Number

0500606421

Code SystemASC Item Number

0500606504

Code SystemASC Item Number

0500606520

Code SystemASC Item Number

0500606603

Code SystemASC Item Number

0500606629

Code SystemASC Item Number

0502000000

Code SystemAnvil 10-Digit Code (legacy)

0502000002

Code SystemAnvil 10-Digit Code (legacy)

0502000004

Code SystemAnvil 10-Digit Code (legacy)

0502000006

Code SystemAnvil 10-Digit Code (legacy)

0502000008

Code SystemAnvil 10-Digit Code (legacy)

0502000010

Code SystemAnvil 10-Digit Code (legacy)

0502000012

Code SystemAnvil 10-Digit Code (legacy)

0502000090

Code SystemAnvil 10-Digit Code (legacy)

0502000092

Code SystemAnvil 10-Digit Code (legacy)

0502000100

Code SystemAnvil 10-Digit Code (legacy)

0502000102

Code SystemAnvil 10-Digit Code (legacy)

0502000104

Code SystemAnvil 10-Digit Code (legacy)

0502000108

Code SystemAnvil 10-Digit Code (legacy)

0502000136

Code SystemAnvil 10-Digit Code (legacy)

0502000140

Code SystemAnvil 10-Digit Code (legacy)

0502008010

Code SystemAnvil 10-Digit Code (legacy)

0502008020

Code SystemAnvil 10-Digit Code (legacy)

Specifications

BrandAFCON
Figure NumberAF001
MaterialSteel
FinishPlain, Electro Galvanized
Pipe TypeSteel
Pipe ConnectionSeismic Brace
SolutionsMechanical & Plumbing Systems, Commercial & Residential, Data Centers, Industrial, Energy & Power, Mining, Fire Protection, Oil & Gas, Water & Wastewater
Size RangeService Pipe: 1" through 4", Brace Pipe: 1" or 1 1/4" Sch. 40
ServiceDesigned to rigidly brace and restrain piping systems subjected to lateral seismic loads. May also be installed to brace piping systems subjected to vertical seismic loads. For vertical load capacities, reference OSHPD OPM-0351-13.
ApprovalscULus Listed (UL 203a) and FM Approved (FM 1950-10 & FM 1950-13). OSHPD Pre-Approved (OPM-0351-13 and OPA-2804-10). Complies with the hanging and bracing requirements listed in NFPA 13.
FeaturesField adjustable design requires no threading of the brace pipe; Indicator clip provides a visual indication that the desired torque value has been achieved
Installation Instructions
Place the 3/8" diameter threaded rod hoop over the service pipe and slide the Sch. 40 brace pipe through the open ends of the threaded rod hoop. The end of the brace pipe must extend at least 2" past the channel bracket.; Note: The brace pipe may be installed above or below the service pipe.; Ensure brace pipe is set to the desired installation brace angle.; Torque hex nuts alternately and equally to the listed torque. Ensure the indicator clip is completely flattened and the brace pipe is tight against the service pipe.; For riser/4-way brace installations, two Q Brace clamps must be installed within 6" of each other.; Fire Protection applications shall also be installed per the requirements of NFPA 13 and local codes.
OrderingSpecify service pipe size, brace pipe size, figure number, finish and description.
CategorySupport Systems > Seismic Bracing > Seismic Braces
Equivalent ProductsAnvil 770; AFCON 001, 020; PHD 010; Tolco 1000

PDF Documents