AF771 Sway Brace Swivel Attachment

Scraped SKU: 82780 2026-06-05 01:11:08

Attributes

BrandAFCON
Figure NumberAF771
MaterialSteel
FinishPlain, Galvanized
Filter Attributes
{"Brand":"AFCON","Figure Number":"AF771","Material":"Steel","Finish":"Plain, Galvanized","Pipe Type":"Steel","Pipe Connection":"Seismic Brace","Solutions":"Mechanical & Plumbing Systems, Commercial & Residential, Data Centers, Industrial, Energy & Power, Mining, Fire Protection, Oil & Gas, Water & Wastewater","Size Range":"Brace Pipe: 1\" or 1 1/4\" Sch. 40, Anchor Size: 1/2\" through 3/4\"","Service":"A seismic swivel attachment designed to connect brace pipe to the building structure or to a seismic structural attachment. The Sway Brace Swivel Attachment rigidly braces piping systems subjected to horizontal seismic loads. The Sway Brace Swivel Attachment may also be installed to rigidly brace piping systems subjected to vertical seismic loads. For vertical load capacities, reference OSHPD OPM-0351-13.","Approvals":"cULus Listed (UL 203a) and FM Approved (FM 1950-10 & FM 1950-13). OSHPD Pre-Approved (OPM-0351-13 and OPA-2804-10). Complies with the hanging and bracing requirements listed in NFPA 13.","Features":"Field adjustable design requires no threading of the brace pipe; Shear off bolt provides a visual indication that the desired torque value has been achieved; True concentric loading of the brace pipe","Installation Instructions":"Insert anchor through the mounting hole and into the structure or seismic structural attachment.; For connection to Fig. AF772, AF778, and AF779 seismic structural attachments, the bolt and nuts shall be installed wrench tight (typically finger tight plus 1/4 to 1/2 turns).; For connection to concrete, wood, timber, steel, and other structures, install fasteners per the fastener manufacturer’s installation instructions.; Insert Sch. 40 brace pipe into the brace socket until the brace pipe bottoms out.; Torque shear off bolt until head shears off.; Check the cross bolt and nut and ensure the nut is wrench tight.; Fire Protection applications shall also be installed per the requirements of NFPA 13 and local codes.","Ordering":"Specify brace pipe size, fastener size, figure number, finish and description.","Category":"Support Systems > Seismic Bracing > Seismic Braces","Equivalent Products":"Anvil 771; AFCON 077; Tolco 909"}
Equivalent Products{"manufacturer":"Anvil","productNumber":"771"}, {"manufacturer":"AFCON","productNumber":"077"}, {"manufacturer":"Tolco","productNumber":"909"}
Upc Codes690291233098, 652808006243, 652808006250, 690291233104, 652808006267, 652808006274, 690291242991, 652808006281, 652808006298, 690291243004, 652808006304, 652808006311, 69029123309, 69029123310, 69029124299, 69029124300
Algolia Submittal/resource/AF771 Sway Brace Swivel Attachment Submittal
Gtin690291233098

Description

Size Range: Brace Pipe: 1" or 1 1/4" Sch. 40, Anchor Size: 1/2" through 3/4" Material: Ductile Iron with Carbon Steel Hardware Finish: Plain or Electro-Galvanized per ASTM B633 Service: A seismic swivel attachment designed to connect brace pipe to the building structure or to a seismic structural attachment. The Sway Brace Swivel Attachment rigidly braces piping systems subjected to horizontal seismic loads. The Sway Brace Swivel Attachment may also be installed to rigidly brace piping systems subjected to vertical seismic loads. For vertical load capacities, reference OSHPD OPM-0351-13. Approvals: cULus Listed (UL 203a) and FM Approved (FM 1950-10 & FM 1950-13). OSHPD Pre-Approved (OPM-0351-13 and OPA-2804-10). Complies with the hanging and bracing requirements listed in NFPA 13. Features: Field adjustable design requires no threading of the brace pipe Shear off bolt provides a visual indication that the desired torque value has been achieved True concentric loading of the brace pipe Installation Instructions: Insert anchor through the mounting hole and into the structure or seismic structural attachment. For connection to Fig. AF772, AF778, and AF779 seismic structural attachments, the bolt and nuts shall be installed wrench tight (typically finger tight plus 1/4 to 1/2 turns). For connection to concrete, wood, timber, steel, and other structures, install fasteners per the fastener manufacturer’s installation instructions. Insert Sch. 40 brace pipe into the brace socket until the brace pipe bottoms out. Torque shear off bolt until head shears off. Check the cross bolt and nut and ensure the nut is wrench tight. Fire Protection applications shall also be installed per the requirements of NFPA 13 and local codes. Ordering: Specify brace pipe size, fastener size, figure number, finish and description.

Variations (12)

0500601000

Code SystemASC Item Number

0500601002

Code SystemASC Item Number

0500601004

Code SystemASC Item Number

0500601026

Code SystemASC Item Number

0500601028

Code SystemASC Item Number

0500601030

Code SystemASC Item Number

0500607007

Code SystemASC Item Number

0500607009

Code SystemASC Item Number

0500607011

Code SystemASC Item Number

0500607023

Code SystemASC Item Number

0500607025

Code SystemASC Item Number

0500607027

Code SystemASC Item Number

Specifications

BrandAFCON
Figure NumberAF771
MaterialSteel
FinishPlain, Galvanized
Pipe TypeSteel
Pipe ConnectionSeismic Brace
SolutionsMechanical & Plumbing Systems, Commercial & Residential, Data Centers, Industrial, Energy & Power, Mining, Fire Protection, Oil & Gas, Water & Wastewater
Size RangeBrace Pipe: 1" or 1 1/4" Sch. 40, Anchor Size: 1/2" through 3/4"
Service
A seismic swivel attachment designed to connect brace pipe to the building structure or to a seismic structural attachment. The Sway Brace Swivel Attachment rigidly braces piping systems subjected to horizontal seismic loads. The Sway Brace Swivel Attachment may also be installed to rigidly brace piping systems subjected to vertical seismic loads. For vertical load capacities, reference OSHPD OPM-0351-13.
ApprovalscULus Listed (UL 203a) and FM Approved (FM 1950-10 & FM 1950-13). OSHPD Pre-Approved (OPM-0351-13 and OPA-2804-10). Complies with the hanging and bracing requirements listed in NFPA 13.
FeaturesField adjustable design requires no threading of the brace pipe; Shear off bolt provides a visual indication that the desired torque value has been achieved; True concentric loading of the brace pipe
Installation Instructions
Insert anchor through the mounting hole and into the structure or seismic structural attachment.; For connection to Fig. AF772, AF778, and AF779 seismic structural attachments, the bolt and nuts shall be installed wrench tight (typically finger tight plus 1/4 to 1/2 turns).; For connection to concrete, wood, timber, steel, and other structures, install fasteners per the fastener manufacturer’s installation instructions.; Insert Sch. 40 brace pipe into the brace socket until the brace pipe bottoms out.; Torque shear off bolt until head shears off.; Check the cross bolt and nut and ensure the nut is wrench tight.; Fire Protection applications shall also be installed per the requirements of NFPA 13 and local codes.
OrderingSpecify brace pipe size, fastener size, figure number, finish and description.
CategorySupport Systems > Seismic Bracing > Seismic Braces
Equivalent ProductsAnvil 771; AFCON 077; Tolco 909

PDF Documents